DEHN DSH ZP B2 LSG A - Combined arrester, TT/TN-S (3+1 configuration)
364.43 EUR
Access the complete sheet with information, compare prices and discover the features of PRODUCTNAME, available at the price of PRICE CURRENCY; it falls into the CATEGORY NAME; the sale is managed by SELLER NAME and the production is done by MANUFACTURER NAME.
DEHNshield ZP B2 LSG A TT 255
Combined arrester for TT and TN-S systems for use in the main power supply system (3+1 configuration) in buildings without external lightning protection (also with overhead line supply).
EAN: 4013364449749
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
DEHNshield ZP B2 LSG A TT 255
Combined arrester for TT and TN-S systems for use in the main power supply system (3+1 configuration) in buildings without external lightning protection (also with overhead line supply).
- DEHNshield DSH ZP B2 LSG A TT 255 combined arrester
- 4-pole combined arrester for 230/400 V
- TT and TN(C)-S systems
- For use upstream of the meter panel according to VDE-AR-N 4100
- Type 1 + type 2 + type 3 surge arresters in accordance with EN 61643-11
- Includes 2 x 230 V power supply (N and L)
- For the intelligent measuring system according to VDE-AR-N 4100
- Includes a single-pole B6 circuit breaker for the power supply
- With sealable protective cover and two sockets each
- and plugs for easy wiring.
- High-performance, end-device-friendly RAC spark gap technology
- Can be mounted directly on a 40 mm busbar system, without needing tools
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Total lightning current (10/350): 30 kA
- Follow current extinguishing capacity: 25 kAeff
- Energy coordination in accordance with DIN EN 62305-4 to
- Red/Line series arresters and directly to the end device
EAN: 4013364449749
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
Comparison of Similar Products
Ready-to-connect, application-optimised combined arrester for TT and TN-S systems (3+1 configuration), with potential-free signalling contact.
- DEHNshield TT 255 FM combined arrester
- 4-pin combined arrester for 230/400 V TT and TN (C) S systems
- Width 4 TE, with remote contact
- Arrester type 1 + type 2 in accordance with EN 61643-11
- Optimised for use in compact electrical installations
- Spark gap technology with follow-current limitation
- Fault indicator
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Lightning surge current (10/350): 50 kA
- Energetic coordination according to DIN EN 62305-4
- Red/Line series arrester and directly to the end device
Ready-to-connect, application-optimised combined arrester for TT and TN-S systems for use in the main power supply system (3+1 circuit) in residential buildings without external lightning protection (also with overhead line supply). With potential-free remote signalling contact.
Ready-to-connect, application-optimised combined arrester for TN-S systems for use in the main power supply system (4+0 circuit) in residential buildings without external lightning protection (also with overhead line supply). With potential-free remote alarm.
- DEHNshield DSH ZP B2 TNS 255 combined arrester
- 4-pole combined arrester for 230/400 V TN-S systems
- For use upstream of the meter panel according to VDE-AR-N 4100
- Type 1 + type 2 + type 3 surge arresters in accordance with EN 61643-11
- Powerful and gentle on end devices
- RAC spark gap technology
- With Click + Power connection technology:
- Mounted completely tool-free on
- 40 mm busbar system
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Total lightning current (10/350): 30 kA
- Follow current extinguishing capacity: 25 kAeff
- Energy coordination in accordance with DIN EN 62305-4 to
- Red/Line series arresters
- Also directly to the end device
- Space-saving width of 38 mm for
- compact use with infeed adapter
- Snap-on cover clip for flexible sizing
- (Max. 3 SU) in compliance with DIN VDE 0603-1
- �Type 1 + type 2 + type 3 combined arrester based on spark gap technology, meets the minimum requirement according to DIN VDE 0100-534 for the nominal leakage surge current in as well as the Iimp lightning leakage current in overhead line power supplies
- �Simple, quick and completely tool-free installation - just snap onto the 40-mm busbar system
- �Enables end device protection
- �A narrow width of just 38 mm allows the DEHNshield ZP to be combined with an infeed adapter and therefore enables installation
- between two SH switches in a single meter field
- �A matching cover clip according to DIN VDE 0603-1 for each commercially available meter field is included in the scope of delivery
- DEHNshield DSH ZP B2 SG TNS 255 combination arrester
- 4-pole combined arrester for 230/400 V TN-S systems
- For use upstream of the meter panel according to VDE-AR-N 4100
- Type 1 + type 2 + type 3 surge arresters in accordance with EN 61643-11
- Includes 2 x 230 V power supply (N and L)
- For the intelligent measuring system
- Integrated replaceable device protection fuse 6.3 A fast
- With 25 kA breaking capacity
- Includes integrated spare fuse in the device
- Powerful and gentle on end devices
- RAC spark gap technology
- With Click + Power connection technology:
- Mounted completely tool-free on
- 40 mm busbar system
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Total lightning current (10/350): 30 kA
- Follow current extinguishing capacity: 25 kAeff
- Energy coordination in accordance with DIN EN 62305-4 to
- Red/Line series arresters
- Also directly to the end device
- Space-saving width of 38 mm for
- compact use with infeed adapter
- Snap-on cover clip for flexible sizing
- (Max. 3 SU) in compliance with DIN VDE 0603-1
Ready-to-connect, application-optimised combined arrester for TN-C systems for use in the main power supply system (3+0 configuration) in residential buildings without external lightning protection (also with overhead line supply), with potential-free remote signalling contact.
Combined arrester for TN-C systems for use in the main power supply system (3+0 configuration) in residential buildings without external lightning protection (also with overhead line supply) includes overcurrent-protected 230 V power supply for space for additional applications/closing point meter position according to VDE-AR-N 4100.
- DEHNshield DSH ZP B2 SG TNC 255 combination arrester
- 3-pole combined arrester for 230/400 V TN-C systems
- For use upstream of the meter panel according to VDE-AR-N 4100
- Type 1 + type 2 + type 3 surge arresters in accordance with EN 61643-11
- Includes 2 x 230 V power supply (N and L)
- For the intelligent measuring system
- Integrated replaceable device protection fuse 6.3 A fast
- With 25 kA breaking capacity
- Includes integrated spare fuse in the device
- Powerful and gentle on end devices
- RAC spark gap technology
- With Click + Power connection technology:
- Mounted completely tool-free on
- 40 mm busbar system
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Total lightning current (10/350): 22.5 kA
- Follow current extinguishing capacity: 25 kAeff
- Energy coordination in accordance with DIN EN 62305-4 to
- Red/Line series arresters
- Also directly to the end device
- Space-saving width of 38 mm for
- compact use with infeed adapter
- Snap-on cover clip for flexible sizing
- (Max. 3 SU) in compliance with DIN VDE 0603-1
Combined arrester for TT and TN-S systems for use in the main power supply system (3+1 configuration) in residential buildings without external lightning protection (also with overhead line supply).
Tested type 1+type 2+type 3 combined arrester in accordance with DIN EN 61643-11 for TT and TN-S systems (3+1 configuration), can be installed completely without tools using Click+Power connection technology for the 40 mm busbar system and push-in ground terminal. For use in the main power supply system in accordance with DIN VDE 0100-443 for buildings (also with overhead line supply, without external lightning protection system). A matching cover clip in accordance with DIN VDE 0603-1 for each commercially available meter field is included in the scope of delivery.
- DEHNshield DSH ZP 2 TNS 255 combined arrester
- 4-pole combined arrester for 230/400 V TN-S systems
- For use upstream of the meter panel according to VDE-AR-N 4100
- Type 1 + type 2 + type 3 surge arresters in accordance with EN 61643-11
- Powerful and gentle on end devices
- RAC spark gap technology
- With Click + Power connection technology:
- Mounted completely tool-free on
- 40 mm busbar system
- Maximum continuous voltage: 255 V AC
- Protection level: <= 1.5 kV
- Total lightning current (10/350): 50 kA
- Follow current extinguishing capacity: 25 kAeff
- Energy coordination in accordance with DIN EN 62305-4 to
- Red/Line series arresters,
- As well as directly to the end device
- Space-saving width of 38 mm for
- compact use with infeed adapter
- Snap-on cover clip for flexible sizing
- (Max. 3 SU) in compliance with DIN VDE 0603-1
- Ready-to-connect, application-optimised Surge Protection Combination type 1 + type 2 based on spark gap
- Space-saving spark gap technology with just 1 TE/pin enables a compact design
- Meets minimum requirements for lightning current discharge capacity according to VDE 0100-534
- Enables compact lightning potential compensation, including end device protection
- Discharge capacity up to 50 kA (10/350 µs)
- Function/defect indication by green-red marking in the viewing window
- High follow current extinguishing capacity (Ifi = 25 kAeff)
- Ready-to-connect complete unit consisting of base part and inserted protection modules
- Energy co-ordinated within the Red/Line product family
- High discharge capacity thanks to powerful zinc oxide varistors/spark gaps
- High level of device safety thanks to ''Thermo-Dynamic-Control'' arrester monitoring
- Simple, tool-free protection module replacement by module locking system with module release button
- Vibration and shock-tested in accordance with EN 60068-2
- Surge arrester with ACI technology: DEHNguard M TT ACI 275 FM
- 4-pin modular, plugin surge arrester
- with integrated ACI switch/spark gap
- for 230/400 V TT and TN-S systems, width 4TE
- With remote alarm
- Type 2 surge arresters in accordance with EN 61643-11
- Maximum continuous voltage: 275 V ac
- Protection level: <= 1.5 kV
- Rated surge current: 20 kA
- No additional external backup is required
- Energetic coordination according to DIN EN 62305-4
- Red/Line series arresters
- Mech. Fault indicator for surge arrester
- Universally applicable Surge Protection Device, consisting of base element and plug-in protection module
- High discharge capacity due to powerful zinc oxide varistor
- High device safety due to ''Thermo-Dynamic-Control'' arrester monitoring
- Energetically coordinated within the Red/Line product family
- Function / defect indication by green-red marking in the viewing window
- Narrow design (modular construction) according to DIN 43880
- Multifunctional connection for conductors and comb rails
- Simple, tool-free protection module change due to module release system with module release button
- Vibration and shock tested according to EN 60068-2
- Ready-to-connect complete unit consisting of base part and inserted protection modules
- Energy coordinated within the Red/Line product family
- High discharge capacity thanks to powerful zinc oxide varistors/spark gaps
- High level of device safety thanks to ''Thermo-Dynamic-Control'' arrester monitoring
- Simple, tool-free protection module replacement via module locking system with module release button
- Vibration and shock-tested in accordance with EN 60068-2
Space-saving, compact combination surge arrester in a plastic surface-mounted housing with push-in technology and status indicator, designed to protect a two-wire, earth-potential-free, symmetrical interface, in particular telecommunications interfaces up to VVDSL and G.fast (up to 1 Gbit/s). Option for direct or indirect shield earthing. On the output side, connection of either a twisted pair cable or a patch cable with an RJ45 connector is possible.
- DEHNbox DBX TC B 180 compact surge arrester
- Modular compact arrester
- of arrester class Type 1/P2
- for protecting a twin-core cable
- at telecommunications interfaces,
- featuring tool-free quick-connect technology,
- integrated strain relief and status indicator
- Rated current at 40°C (IL): 1 A
- D1 Total surge current (10/350 µs) (Iimp): 7.5 kA
- C2 Total rated surge current (8/20 µs) (In): 20 kA
Modular combined arrester for single-phase TT and TN systems (1+1 configuration) designed to protect the 230 V power supply to mobile communications systems.
- Ready-to-connect combination arrester type 1 + type 2 based on spark gap, consisting of base part and inserted protection module
- Compact design combined with the highest safety standards thanks to Rapid Arc Control (RAC)
- enables end device protection
Modular combination arrester for TT and TN-S systems (3+1 configuration) for protecting the 230/400 V power supply to mobile communications systems.
- Ready-to-connect combination arrester type 1 + type 2 based on spark gap, consisting of base part and inserted protection module
- Compact design combined with the highest safety standards thanks to Rapid Arc Control (RAC)
- enables end device protection
- Resi9 iPRF combination arrester ZP, compact design for NAR on 40 mm SaS in snap-on technology
- Type T1+T2+T3
- Without external lightning protection 7.5 kA
- TT/TNS system 3P+N
- Leakage current free
- No remote signalling contact
- Mechanical trip indicator at the front
- Rated leakage current: 12.5 kA
- Max. Leakage current: 40 kA
- Protection level: 1.5 kV
- Voltage: 230 V AC
- Color: traffic white, RAL 9003
- Lightning current carrying capacity according to DIN VDE 0100-443/-534
- The compact design (2 TE = 36 mm width) allows mounting between two SH switches and an additional feeder adapter
Surge Protection Device (SPD) Type 2 with Varistor and wireless link
• Varistor between L - N + wireless link between N - PE
• For 1-phase TN-S and TT grids
• Width: 35 mm
• For DIN EN 60715 TH35 mounting rail
According to the principles of surge protection standard EN 62305, can be used in zones LPZ 1, LPZ 2 or LPZ 3
• Conforms to EN 61643-11, requirements for surge protectors for use in low-voltage systems
- Type T1+T2+T3
- Without external lightning protection 7.5 kA
- TT/TNS system 3P+N
- Leakage current free
- Version with remote monitoring contact, potential-free, 1 changeover contact
- Voltage tap with integrated fine-wire fuse according to VDE-AR-N 4100 (TAR NS)
- Fine-wire fuse can be replaced without dismantling the combined arrester
- Rated leakage current: 12.5 kA
- Max. leakage current: 40 kA
- Protection level: 1.5 kV
- Voltage: 230 V AC
- Color: traffic white, RAL 9003
- Compact design (2 TE = 36 mm width) allows mounting between two SH switches and an additional feeder adapter
- Enables support of power distribution 4.0
Combination arrester for lightning currents type 1+2 for mounting on 40 mm busbar systems is installed in 3-phase network systems according to lightning protection class III and IV by simply snapping it onto the busbar system.
Advantages
- small space requirement
- modular construction
- additional interlocking
- network form: TNC 3+0 / TT 3+1 or TNS 4+0 circuit
- Iimp /Pole = 7,5 kA
- no leakage current / no mains follow current
Important features
- tested according to EN 61643-11:2012,
- with exchangeable plug-in modules and vibration-proof locking device
- for mounting on 40mm busbar systems
- with defect indication in viewing window, without remote signalling contact
- energy coordination according to DIN EN 62305-4
Technical features
- highest continuous voltage L-N/N-PE (Uc): 255 V / 255 V AC
- lightning impulse current (10/350 µs) L-N/N-PE (Iimp): 7.5 kA / 30 kA
- maximum leakage surge current (8/20 µs) L-N/N-PE (Imax): 60 kA / 100 kA
- Protection level (Up): < 1.5 kV
- short-circuit strength (Isccr): 25 kA
- maximum back-up fuse: 160 A gL/gG
- Operating temperature: -40°C ... +80°C
deliver, assemble and connect ready for operation!
Surge Protection Device (SPD) type 2
• Plug-in Varistor module
• Varistor between L - N, L - PE or N - PE
• For 1-phase TN-S and TT grids between L - N, L - PE or N - PE
• For 1-phase TN-C grids between L - PEN
• Width: 17.5 mm
• For DIN EN 60715 TH35 mounting rail
According to the principles of surge protection standard EN 62305, can be used in zones LPZ 1, LPZ 2 or LPZ 3
• Conforms to EN 61643-11, requirements for surge protectors for use in low-voltage systems
Surge Protection Device (SPD) type 2
• Plug-in varistor modules
• Varistor between L1, L2, L3 - N + wireless link between N - PE
• For 3-phase TN-S and TT grids
• Width: 70 mm
• For DIN EN 60715 TH35 mounting rail
According to the principles of surge protection standard EN 62305, can be used in zones LPZ 1, LPZ 2 or LPZ 3
• Conforms to EN 61643-11, requirements for surge protectors for use in low-voltage systems