CARLO GAVAZZI A82-20250 - A82 monitoring relay, current transformer, RMS measurement, 250
194.45 EUR
Access the complete sheet with information, compare prices and discover the features of PRODUCTNAME, available at the price of PRICE CURRENCY; it falls into the CATEGORY NAME; the sale is managed by SELLER NAME and the production is done by MANUFACTURER NAME.
Current transformers with RMS measurement for the current ranges 25, 50, 100, 250 or 500 AAC. Output current ranges according to IEC 60381-1 (A 82-10, A 82-20) or output voltage according to IEC 60381-2 (A 82-30). The A 82-10 and A 82-20 converters can be used with the following monitoring relays: DIB01, PIB01, DIC01, PIC01. A 82-30 can be used with DUB01, PUB01, DUB71, DUC01 or PUC01. The converters are designed for direct PLC connection. A green LED on the enclosure side indicates whether the operating voltage is switched on.
5 input current ranges:
Output current/voltage ranges:
Simple interface for PLC or monitoring relay
EAN: 5709870081601
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
Current transformers with RMS measurement for the current ranges 25, 50, 100, 250 or 500 AAC. Output current ranges according to IEC 60381-1 (A 82-10, A 82-20) or output voltage according to IEC 60381-2 (A 82-30). The A 82-10 and A 82-20 converters can be used with the following monitoring relays: DIB01, PIB01, DIC01, PIC01. A 82-30 can be used with DUB01, PUB01, DUB71, DUC01 or PUC01. The converters are designed for direct PLC connection. A green LED on the enclosure side indicates whether the operating voltage is switched on.
5 input current ranges:
- 0 - 25 AAC
- 0 - 50 AAC
- 0 - 100 AAC
- 0 - 250 AAC
- 0 - 500 AAC
Output current/voltage ranges:
- A 82-10: 0 - 20 mADC (current source)
- A 82-20: 4 - 20 mADC (load)
- A 82-30: 0 - 10 VDC
Simple interface for PLC or monitoring relay
EAN: 5709870081601
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
Comparison of Similar Products
- Undervoltage measuring relay for DC voltage
- Monitors whether the operating voltage drops below the set limit
- Measures the voltage of the intrinsic power supply
- Measurement ranges: 8 - 28 V DC and 38 - 58 V DC
- Adjustable hysteresis: 4 to 50%
- Output: 1-pin 5 A changeover contact, live in idle mode
- LED indicators for relays and operating voltage ON
- 17.5 mm enclosure according to DIN 43880
- DIN rail mounting according to DIN EN 50 022
5 input current ranges:
- 0 - 25 AAC
- 0 - 50 AAC
- 0 - 100 AAC
- 0 - 250 AAC
- 0 - 500 AAC
Output current/voltage ranges:
- A 82-10: 0 - 20 mADC (current source)
- A 82-20: 4 - 20 mADC (load)
- A 82-30: 0 - 10 VDC
Simple interface for PLC or monitoring relay
- 3-pole
- Zero-voltage switch for three-phase current
- Dimensions (W x H x D): 73.5 x 41 x 103 mm
- Control input: 4 - 32 V DC
- Switching voltage: 24 - 440 V AC
- Switching current: 3 x 25 A
- Load current min.: 150 mA
- Load current max.: 25 A
- High blocking voltage
- DC or AC control voltage
- Integrated over-voltage protection
- Option: overtemperature protection with alarm output
- LED display for control input and status
- Overtemperature alarm
- UL-certified motor power
- AC/DC overcurrent or undercurrent monitoring relay, measuring the true rms value
- Current measured via the integrated measuring resistor
- Measuring range can be selected using DIP switches
- Measurement range spans 0.1 mA to 10 A AC/DC
- Sets the permissible overcurrent and undercurrent on a relative scale
- Hysteresis can be adjusted on a relative scale
- Adjustable switch-on delay (0.1 to 30 s)
- Programmable self-hold or locking at the set limit
- Output: 1 changeover contact, 8 A, on N.D. (normally deactivated) or N.A. (normally activated)
- Version: For DIN rail mounting according to DIN/EN/EC 60715 (DIB01) or as plugin module (PIB01)
- 22.5 mm enclosure according to Euro standard (DIB01) or 36 mm plugin module (PIB01)
- LED indicator for relays, alarms and operating voltage ON
- Galvanically isolated power supply, DIB01 PIB01
- 3-pole
- Zero-voltage switch for three-phase current
- Dimensions (W x H x D): 73.5 x 41 x 103 mm
- Control input: 4 - 32 V DC
- Switching voltage: 24 - 440 V AC
- Switching current: 3 x 55 A
- Load current min.: 250 mA
- Load current max.: 55 A
- High blocking voltage
- DC or AC control voltage
- Integrated over-voltage protection
- Option: overtemperature protection with alarm output
- LED display for control input and status
- Overtemperature alarm
- UL-certified motor power
- 3-pole
- Zero-voltage switch for three-phase current
- Dimensions (W x H x D): 73.5 x 41 x 103 mm
- Control input: 4 - 32 V DC
- Switching voltage: 42 - 660 V AC
- Switching current: 3 x 55 A
- Load current min.: 250 mA
- Load current max.: 55 A
- High blocking voltage
- DC or AC control voltage
- Integrated over-voltage protection
- Option: overtemperature protection with alarm output
- LED display for control input and status
- Overtemperature alarm
- UL-certified motor power
- 3-pole
- Zero-voltage switch for three-phase current
- Dimensions (W x H x D): 73.5 x 41 x 103 mm
- Control input: 24 - 50 V DC
- Switching voltage: 42 - 660 V AC
- Switching current: 3 x 55 A
- Load current min.: 250 mA
- Load current max.: 55 A
- High blocking voltage
- DC or AC control voltage
- Integrated over-voltage protection
- Option: overtemperature protection with alarm output
- LED display for control input and status
- Overtemperature alarm
- UL-certified motor power
Tamper-proof, no user adjustment options. The RSBT automatically adjusts its internal parameters to ensure optimum startup in all conditions.
- Self-learning algorithm that automatically adjusts the start parameters to the load
- No user customisations required
- Limits the starting current of 3-phase compressors
- Dimensions (W x H x D): 45 x 125 x 81 mm
- The monitoring relay can be used from 100 to 690 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag lets you respond to alarm conditions
- LED display for the operating status, alarm and relay status
- Two mounting versions are available as DIN rail (DPC01) or plugin module (PPC01)
- Adjustable ON delay to prevent faults during starting or starting up
- High immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detecting correct phase sequence, phase loss, unbalance and deviation
- Setpoints for overvoltage and undervoltage, unbalance and deviation can be adjusted using the front adjustment wheel
- Time delay
- Two changeover relay outputs
- The monitoring relay can be used from 208 to 480 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag enables a flexible response to alarm conditions
- LED indicator for operating status, alarm and relay status allows for quick troubleshooting
- Two mounting versions: available as DIN rail (DPB01) or plugin module (PPB01)
- Adjustable ON delay: To prevent faults during starting or starting up
- Ultra-high harmonic immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detection of the correct phase sequence (not for N-ended versions) and phase loss
- Overvoltage and undervoltage setpoints can be adjusted using the front setting wheel
- Time delay
- Centre-zero relay output
- The monitoring relay can be used from 208 to 480 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag enables a flexible response to alarm conditions
- LED indicator for operating status, alarm and relay status allows for quick troubleshooting
- Two mounting versions: available as DIN rail (DPB01) or plugin module (PPB01)
- Adjustable ON delay: To prevent faults during starting or starting up
- Ultra-high harmonic immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detection of the correct phase sequence (not for N-ended versions) and phase loss
- Overvoltage and undervoltage setpoints can be adjusted using the front setting wheel
- Time delay
- Centre-zero relay output
- Wide voltage range: The monitoring relay range spans 208 to 690 V AC
- LED indicator for operating status, alarm and relay status allows for quick troubleshooting
- Regeneration voltage detection to detect phase losses even when the motor is running
- Two mounting versions are available as DIN rail (DPA01) or plugin (PPA01)
- Three-line three-phase mains monitoring (3P)
- Detection of the correct phase sequence and phase loss
- Centre-zero relay output
- Overcurrent or undercurrent monitoring relay, measuring the true rms value
- Current measured via current transformers
- Measuring range can be selected using DIP switches
- Measurement range from 2 A to 100 A AC
- Sets the permissible overcurrent and undercurrent on a relative scale
- Hysteresis can be adjusted on a relative scale
- Adjustable switch-on delay (0.1 to 30 s)
- Programmable self-hold or locking at the set limit
- Output: 1 changeover contact, 8 A, on N.D. (normally deactivated) or N.A. (normally activated)
- For DIN rail mounting DIN/EN/EC 60715
- 22.5 mm enclosure according to Euronorm
- LED indicator for relays, alarms and operating voltage ON
- Galvanically isolated power supply
- Overvoltage monitoring relay for single-phase AC/DC voltage
- Overcurrent monitoring relays for single-phase and triple-phase alternating current with transducer
- Measurement ranges: 2 to 20 V AC/DC, 5 to 50 V AC/DC, 20 to 200 V AC/DC, 50 to 500 V AC/DC and 0.4 to 4 V AC adjusted using DIP switches
- Sets the permissible overvoltage on a relative scale
- Adjustable hysteresis
- Programmable self-hold when the set limit is reached
- Output: 1 changeover contact 8 A normally disabled
- Version: For DIN rail mounting according to DIN EN 50 022 (DUA01) or as plugin module (PUA01)
- 22.5 mm Euro standard enclosure or 36 mm plugin module
- LED indicators for relays and for operating voltage ON
- Galvanically isolated power supply
- 3-pole
- Zero-voltage switch for three-phase current
- Dimensions (W x H x D): 73.5 x 41 x 103 mm
- Control input: 4 - 32 V DC
- Switching voltage: 42 - 660 V AC
- Switching current: 3 x 75 A
- Load current min.: 400 mA
- Load current max.: 75 A
- High blocking voltage
- DC or AC control voltage
- Integrated over-voltage protection
- Option: overtemperature protection with alarm output
- LED display for control input and status
- Overtemperature alarm
- UL-certified motor power
- The Rogowski sensor is an AC current meter
- Unlike current sensors with ferromagnetic current, the linearity of the Rogowski sensor makes it ideal for measuring high currents
- Its operating principle is very simple: A voltage signal (dependent on the primary current trend) which can be reconstructed by means of an integration process, is generated at the ends of the coil around a conductor
- Current transformer cables and busbars
- Class 0.5, currents from 50 to 300 A
- Adaptable DIN rail clip
- Adaptable panel mounting clips
- Two insulated cables/busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 50 to 800 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- Up to six busbars, insulated fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer cables and busbars
- Class 0.5, currents from 50 to 300 A
- Adaptable DIN rail clip
- Adaptable panel mounting clips
- Two insulated cables/busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 40 to 600 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- 2 insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 50 to 800 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- Up to six busbars, insulated fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- 5 A secondary current
- 24 mm hole diameter for primary current up to 300 A
- 36 mm hole diameter for primary current up to 600 A
- Current transformer cables and busbars
- Class 0.5, currents from 50 to 300 A
- Adaptable DIN rail clip
- Adaptable panel mounting clips
- Two insulated cables/busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 40 to 600 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- 2 insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 40 to 600 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- 2 insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer cables and busbars
- Class 0.5, currents from 50 to 300 A
- Adaptable DIN rail clip
- Adaptable panel mounting clips
- Two insulated cables/busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 150 to 1600 A
- Adaptable panel mounting clips
- Up to six insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer cables and busbars
- Class 0.5, currents from 50 to 300 A
- Adaptable DIN rail clip
- Adaptable panel mounting clips
- Two insulated cables/busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- 5 A secondary current
- 24 mm hole diameter for primary current up to 300 A
- 36 mm hole diameter for primary current up to 600 A
- Current transformer busbars
- Class 0.5, currents from 50 to 800 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- Up to six busbars, insulated fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Current transformer busbars
- Class 0.5, currents from 40 to 600 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- 2 insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- 5 A secondary current
- 24 mm hole diameter for primary current up to 300 A
- 36 mm hole diameter for primary current up to 600 A
- Current transformer busbars
- Class 0.5, currents from 40 to 600 A
- Integrated DIN rail clip
- Adaptable panel mounting clips
- 2 insulated busbar fastening screws
- 2-way screw terminal (up to 8-wire connection)
- Sealable terminal cover
- Adjustable time range: 0.1 s to 100 h
- 7x adjustment using the rotary knob:
Op - Response delay
In - Interval
Io - Interval on trigger open
Id - Double interval
Dr - Delay on release
R - Sym. recycler - starts at working time (pulse start)
Rb - Symmetrical recycler - Start with pause time
(Start when pulse ends)
- Automatic or manual start
- Repeatability: = 0.2%
- Output: 1 changeover contact, 5 A or 2 x 1 changeover contacts, 5 A
- Snap-on to DIN rail DIN/EN/EC 60715
- 17.5 mm (DMB51C) or 35.5 mm (DMB71D) DIN rail enclosure (DIN 43880)
- Combined AC and DC operating voltage
- LED function indicators for relay status and operating voltage ON
- Time range: 0.1 s to 100 h
- Time ranges can be set using the rotary knob
- Automatic start
- Repeatability = 0.2%
- Output: 1 changeover contact, 5 A or 2 x 1 changeover contacts, 5 A
- Snap-on to DIN rail DIN/EN/EC 60715
- 17.5 mm (DAA51C) or 35.5 mm (DAA71D) DIN rail enclosure (DIN 43880)
- Combined AC and DC operating voltage
- LED function indicators for relay status and operating voltage ON
- Adjustable time range: 0.1 s to 100 h
- 7x adjustment using the rotary knob:
Op - Response delay
In - Interval
Io - Interval on trigger open
Id - Double interval
Dr - Delay on release
R - Sym. recycler - starts at working time (pulse start)
Rb - Symmetrical recycler - Start with pause time
(Start when pulse ends)
- Automatic or manual start
- Repeatability: = 0.2%
- Output: 1 changeover contact, 5 A or 2 x 1 changeover contacts, 5 A
- Snap-on to DIN rail DIN/EN/EC 60715
- 17.5 mm (DMB51C) or 35.5 mm (DMB71D) DIN rail enclosure (DIN 43880)
- Combined AC and DC operating voltage
- LED function indicators for relay status and operating voltage ON
- 5 A secondary current
- 24 mm hole diameter for primary current up to 300 A
- 36 mm hole diameter for primary current up to 600 A
- 5 A secondary current
- 24 mm hole diameter for primary current up to 300 A
- 36 mm hole diameter for primary current up to 600 A