ALLNET 16881PC - ALLNET Powerline phase cou. 3 phases +N + LX
150.47 EUR
Consult the complete sheet with in-depth details, compare prices and identify the features of PRODUCTNAME, available at the cost of PRICE CURRENCY; falls into the CATEGORY NAME; the seller is SELLER NAME and the manufacturer is MANUFACTURER NAME.
ALLNET Powerline ALL16881PC phase coupler/FI signal bridge 3 phases
A phase coupler is required if Powerline PLC devices are installed over different phases.
Please note!! This item may only be installed by authorized specialist workshops.
Phase coupler/signal coupler for Powerline networks for installation in the fuse box (rail mounting).
• ALL16881PC AC 250/440 V 50/60 Hz
• Powerline devices on different phases and circuits can now communicate with each other
• Frequency range 1 ~ 70 MHz
• Installation on DIN RAIL mounting
• Suitable for signal bridging via FI circuit breakers and electricity meters
Connects all the phases of the household power supply and makes the Powerline signal on all sockets available in a circuit. Cross connections to other circuits can be established via the fourth LX phase if electricity meters, FI circuit breakers and similar obstacles to Powerline communication must be overcome.
IMPORTANT: 3 phases + ''L/N''. The range is extended in comparison to the standard phase coupler by means of better coupling. Several circuits can be connected with this adapter. Multiple FIs can be bridged
PLEASE NOTE: These devices may only be installed by a skilled electrician,
otherwise there is a risk of fire or electric shock.
EAN: 4038816112415
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
ALLNET Powerline ALL16881PC phase coupler/FI signal bridge 3 phases
A phase coupler is required if Powerline PLC devices are installed over different phases.
Please note!! This item may only be installed by authorized specialist workshops.
Phase coupler/signal coupler for Powerline networks for installation in the fuse box (rail mounting).
• ALL16881PC AC 250/440 V 50/60 Hz
• Powerline devices on different phases and circuits can now communicate with each other
• Frequency range 1 ~ 70 MHz
• Installation on DIN RAIL mounting
• Suitable for signal bridging via FI circuit breakers and electricity meters
Connects all the phases of the household power supply and makes the Powerline signal on all sockets available in a circuit. Cross connections to other circuits can be established via the fourth LX phase if electricity meters, FI circuit breakers and similar obstacles to Powerline communication must be overcome.
IMPORTANT: 3 phases + ''L/N''. The range is extended in comparison to the standard phase coupler by means of better coupling. Several circuits can be connected with this adapter. Multiple FIs can be bridged
PLEASE NOTE: These devices may only be installed by a skilled electrician,
otherwise there is a risk of fire or electric shock.
EAN: 4038816112415
Delivery Cost: 9.95 EUR
Availability: in stock
Delivery Time: 4-5 business days
Condition: new
Comparison of Similar Products
Phase coupler for Powerline networks for installation in the fuse box (rail mounting).
Connects all the phases of the household power supply and makes the Powerline signal on all sockets available in a circuit.
Cross connections to other circuits can be established via the fourth LX phase if electricity meters, FI circuit breakers and similar obstacles to Powerline communication must be overcome.
• 3-phase version with fourth LX-phase for coupling with other networks
• Frequency range 1 - 40 MHz
• AC 250/440 V, 4x 22nFX2, 3-phase
Please note!! This item may only be installed by authorized specialist workshops.
- 5.5 kW
- 380 - 500 V
- Cooling type: Fan
- Number of mains phases: 3 phases
- Mains current: 14.5 A at 500 V for high overload, 20.7 A at 380 V for high overload
Benefits:
30% cost savings thanks to integrated safety functions:
- STO, SS1, SLS, SMS and GDL (safe safety door release) integrated as standard
- No additional costs for contactors, encoders, external
- Reduced wiring due to fewer components
Suitable for difficult environments:
- Use at ambient temperatures up to 60°C
- Standard painted circuit boards (3C3)
- Ideal for material or wood processing
Ideal for pumps, compressors, fans:
- Integrated PID controller and various connection options for pressure and flow control sensors directly on the device.
- High overload capability for efficient operation of all types of compressors
Numerous network connections:
- Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT
- Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet
Simple plug and play installation
- 1.5 kW
- 380 - 500 V
- EMC filter: Integrated EMC filter class C2
- Cooling type: Fan
- Number of mains phases: 3 phases
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload
Benefits:
30% cost savings thanks to integrated safety functions:
- STO, SS1, SLS, SMS and GDL (safe safety door release) integrated as standard
- No additional costs for contactors, encoders, external
- Reduced wiring due to fewer components
Suitable for difficult environments:
- Use at ambient temperatures up to 60°C
- Standard painted circuit boards (3C3)
- Ideal for material or wood processing
Ideal for pumps, compressors, fans:
- Integrated PID controller and various connection options for pressure and flow control sensors directly on the device.
- High overload capability for efficient operation of all types of compressors
Numerous network connections:
- Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT
- Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet
Simple plug and play installation
- 2.2 kW
- 380 - 500 V
- EMC filter: Integrated EMC filter class C2
- Cooling type: Fan
- Number of mains phases: 3 phases
- Mains current: 6.6 A at 500 V for high overload, 8.7 A at 380 V for high overload
Benefits:
30% cost savings thanks to integrated safety functions:
- STO, SS1, SLS, SMS and GDL (safe safety door release) integrated as standard
- No additional costs for contactors, encoders, external
- Reduced wiring due to fewer components
Suitable for difficult environments:
- Use at ambient temperatures up to 60°C
- Standard painted circuit boards (3C3)
- Ideal for material or wood processing
Ideal for pumps, compressors, fans:
- Integrated PID controller and various connection options for pressure and flow control sensors directly on the device.
- High overload capability for efficient operation of all types of compressors
Numerous network connections:
- Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT
- Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet
Simple plug and play installation
- 15 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- 11 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- 0.75 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- Housing type: Compact design.
- 3 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- Housing type: Compact design.
- 7.5 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- 1.1 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- Housing type: Compact design.
- 4 kW
- 380 - 500 V
- EMC filter: Integrated EMC filter class C2
- Cooling type: Fan
- Number of mains phases: 3 phases
- Mains current: 10.6 A at 500 V for high overload, 13.8 A at 380 V for high overload
Benefits:
30% cost savings thanks to integrated safety functions:
- STO, SS1, SLS, SMS and GDL (safe safety door release) integrated as standard
- No additional costs for contactors, encoders, external
- Reduced wiring due to fewer components
Suitable for difficult environments:
- Use at ambient temperatures up to 60°C
- Standard painted circuit boards (3C3)
- Ideal for material or wood processing
Ideal for pumps, compressors, fans:
- Integrated PID controller and various connection options for pressure and flow control sensors directly on the device.
- High overload capability for efficient operation of all types of compressors
Numerous network connections:
- Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT
- Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet
Simple plug and play installation
Motor power: 4 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
- 0.55 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- Housing type: Compact design.
Motor power: 0.75 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
Motor power: 2.2 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
Motor power: 3 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
- 0.37 kW.
- 380 ... 500 V.
- EMC filter: Integrated EMC filter class C2 (filter can be switched off).
- Cooling type: Fan.
- Number of network phases: 3 phases.
- Mains current: 4.9 A at 500 V for high overload, 6.4 A at 380 V for high overload.
- Housing type: Compact design.
Motor power: 0.55 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
Motor power: 1.1 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
Motor power: 1.5 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
Motor power: 0.37 kW.
Supply voltage: 380 ... 500 V.
Number of mains phases: 3 phases.
The book form factor allows a very compact installation in your automation cabinets.
Advantages of ATV320:
30% cost savings due to integrated safety functions:
5 safety functions integrated as standard: safe torque off (STO), safe stop1 (SS1), safe reduced speed (SLS), safe maximum speed (SMS), safe guard door release (GDL).
No additional costs for contactors, encoders, external monitoring modules or option cards.
Reduced wiring costs due to fewer components.
Suitable for difficult environments:
Use at ambient temperatures up to 60 °C.
Standard painted boards (3C3).
Ideal for material or woodworking applications.
Ideal for pumps, compressors, fans:
Integrated PID controller and various connection options for sensors for pressure and flow control directly on the device.
High overload capability for efficient operation of all types of compressors.
Various network connections:
Ethernet: Modbus TCP, Ethernet/IP, Profinet, EtherCAT.
Serial: Modbus RTU, CANopen, Profibus DP, DeviceNet.
Plenty of integrated functions:
5 easy-to-use macros (start/stop, operation, stroke movement, general use, PID control, communication bus).
PLC integrated.
16 preset speeds.
Multiple parameter settings via parameter set switching.
External fanless design, 50 °C without derating.
3 analog inputs, FI can be used for signal monitoring.
DC supply for direct stop.
Common DC link with regenerative unit ATVRegen.
Jog mode.
PID for fan, pump.
Positioning via limit switches or sensors.
4 sets for parameter set changeover.
Automatic restart.
PM motor with open loop control.
Simple plug & play commissioning.
Combination of ATV320 variable speed drive + TM172SIG gateway:
Combining the Altivar ATV320 drive with the Modicon TM172SIG IIoT gateway gives you the ability to easily receive alarms via email.
- Charging socket that meets the IEC 62196-2 specification
- For mounting on charging stations/wall boxes
- Tested by TÜV Rheinland
- High-quality and sturdy design
- With spring-loaded folding cover
- Contacts: 3x L + N + PE, plus PP + CP
- Cable cross-sections: 5 x 2.5 mm², 2 x 0.5 mm²
- Up to 32 A, 240 V AC/phase
- Contacts for screwing
- With rubber seal on the housing
- Outer diameter (front): 100 mm
- Contacts can be removed individually
- IP54, dust- and splash-proof
- Colour: black
Caution: This plug is fitted with screw contacts.
Note:
As the wiring of charging and adapter cables is complex, installation should only be performed by a professional.
We do not assume any responsibility for any consequential damage resulting from improper handling or installation.
- Charging socket that meets the IEC 62196-2 specification
- For mounting on charging stations/wall boxes
- Tested by TÜV Rheinland
- High-quality and sturdy design
- With spring-loaded folding cover
- Contacts: 3x L + N + PE, plus PP + CP
- Cable cross-sections: 5 x 2.5 mm², 2 x 0.5 mm²
- Up to 16 A, 240 V AC/phase
- Contact element for crimping or soldering
- With rubber seal on the housing
- Outer diameter (front): 100 mm
- Contacts can be removed individually
- IP54, dust- and splash-proof
- Colour: black
Note:
As the wiring of charging and adapter cables is complex, installation should only be performed by a professional.
We do not assume any responsibility for any consequential damage resulting from improper handling or installation.
- Power supply AC: 110 - 240 V, 50 / 60 Hz
- Maximum load up to 16 A per channel with up to 48 A for the whole device
- 3 Channels
- Wi-Fi 802.11 b/g/n (2,4 GHz)
- 1x RJ45 LAN Port
- Bluetooth
3 channels DIN rail relay switch with Wi-Fi, LAN and Bluetooth connection
Professional 3 channels relay with Wi-Fi, LAN, and Bluetooth connection, suitable for home and facility automation with remote control.
DIN rail mountable inside a breaker box. Enhanced safety features and compatible with most used home automation platforms.
- Dry contacts
- Wide range of voltage support
- DC switching
- 3-phase control
- LAN, Wi-Fi, and Bluetooth connectivity
Shelly Pro 3 is a three-phase, 3-channel relay supporting up to 48 A total output and 16 A per channel.
It’s equipped with potential-free outputs (dry contacts) and can switch 3 completely independent circuits, including 3-phase ones.
Shelly Pro 3 is enhanced with scripting functionalities, allowing users to set custom automation scenes based on various occurrences such as weather forecast, wind force forecast, etc.
Enjoy easy office, home, and facility automation!
Endless use applications
With the power to control and Shelly Pro 3 can work standalone or be complementary to any existing automation project.
Here are just a few applications worth considering for your home, business facility, or office building:
- Lights automation
Control and monitor 3 individual circuits on different phases. - Garage door control
Control and monitor garage doors from anywhere. - 3-phase heater automation
Suitable for industrial heaters, both air and water. - 3-phase pumps control
Control and monitor 3-phase induction motors. - 3rd party DC systems control
Control low voltage DC systems by dry contact relays
The Nedis portable reversible EV charging box cable is designed for convenience and reliability. This portable device has a CEE 7/7 plug connection, which allows you to charge your electric vehicle effortlessly wherever you go. With adjustable charging capacities from 6 A to 16 A, the charger adapts to the needs of your vehicle.
Stay up-to-date with the full-colour display, which provides real-time data on voltage, performance, charging status and internal temperature. Designed to withstand the elements, this charging box is IP55 rated to ensure performance in harsh conditions. Its robust design guarantees over 10,000 applications, supported by an ABS housing that protects against moisture, dust and sand.
- For the screwless replacement of household reference meters (63 A) in 3-point mounting
- Set of 7 contact pins with locking N-pin, 6x 45 mm and 1x 45 mm
- W x H x D: 5 x 45 x 5 mm
- Accessories for meter cabinet ABN
- Housing material: PA6
- Rated current: 32A
- Number of poles: 5 (3P+N+PE)
- Time position: 6h
- Rated voltage/frequency: 200/346V~ - 240/415V~ / 50+60Hz
- Contacts: Brass nickel plated
- Connection technology: screw terminals
- Protection class: IP44/IP54
- The monitoring relay can be used from 208 to 480 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag enables a flexible response to alarm conditions
- LED indicator for operating status, alarm and relay status allows for quick troubleshooting
- Two mounting versions: available as DIN rail (DPB01) or plugin module (PPB01)
- Adjustable ON delay: To prevent faults during starting or starting up
- Ultra-high harmonic immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detection of the correct phase sequence (not for N-ended versions) and phase loss
- Overvoltage and undervoltage setpoints can be adjusted using the front setting wheel
- Time delay
- Centre-zero relay output
- The monitoring relay can be used from 100 to 690 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag lets you respond to alarm conditions
- LED display for the operating status, alarm and relay status
- Two mounting versions are available as DIN rail (DPC01) or plugin module (PPC01)
- Adjustable ON delay to prevent faults during starting or starting up
- High immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detecting correct phase sequence, phase loss, unbalance and deviation
- Setpoints for overvoltage and undervoltage, unbalance and deviation can be adjusted using the front adjustment wheel
- Time delay
- Two changeover relay outputs
- The monitoring relay can be used from 208 to 480 V AC and from 50 to 400 Hz
- Adjustable voltage levels and time lag enables a flexible response to alarm conditions
- LED indicator for operating status, alarm and relay status allows for quick troubleshooting
- Two mounting versions: available as DIN rail (DPB01) or plugin module (PPB01)
- Adjustable ON delay: To prevent faults during starting or starting up
- Ultra-high harmonic immunity for noisy environments
- Three-line (3P) or four-line (3P + N) three-phase mains monitoring
- Detection of the correct phase sequence (not for N-ended versions) and phase loss
- Overvoltage and undervoltage setpoints can be adjusted using the front setting wheel
- Time delay
- Centre-zero relay output
- Housing material: PA6
- Rated current: 16A
- Number of poles: 5 (3P+N+PE)
- Time position: 6h
- Rated voltage/frequency: 200/346V~ - 240/415V~ / 50+60Hz
- Contacts: Brass nickel plated
- Connection technology: screw terminals
- Protection class: IP44/IP54
